RH2 LED indicators
RH2 has the RGB status LED capability. In the standard firmware, it uses the display described here. Application-controlled lights can provide separate feedback, so first check whether you are looking at charging/status or at a running application's indication. See the RH2 exterior guide for the enclosure layout.
Charging status
The standard RGB charging display changes colour with the approximate battery level:
| Battery level | Charging status colour |
|---|---|
| Below 30% | Red |
| 30% to below 70% | Orange |
| 70% to below 90% | Yellow-green |
| 90% or more | Green |
Brightness varies in steps about every half-second while charging below approximately 99%. At about 99% or above, that variation stops. Green starts at about 90%; it is not an exact full-battery indication or proof of an RTK fix.
RH2 charging colour
Yellow-green · brightness step 1 of 5
Yellow-green at 80%. Brightness increases in five steps, about 0.5 seconds each, then repeats.
Enable JavaScript to adjust this example.
Do not apply the four-bar, 95% charging rule from Pro3 or the older ProN/Zero/Enviro guides to RH2.
Off-charge status
When armed and active, the standard status display can reflect positioning state and low battery. A configured resting colour takes precedence over that default indication, and an inactive device normally turns the status display off. Applications and alarms can also control the lights.
For this reason, a green or red light by itself is not a reliable statement of RTK accuracy, upload success or a hardware fault. Check the application's positioning/accuracy information and the latest successful communication.
Application-controlled feedback
The Survey application flashes green for a successfully submitted survey point and red for a submission error. Those are application events, not the charging colour table above. Other applications can choose different patterns.
For another device or an unfamiliar pattern, start with the LED guide.